Fasteners must be located more than 12 mm from plank edges and 20 mm from plank ends. When installing in an overlapping plank cladding style, plank installation must be started at the bottom of the frame. The subsequent row of planks should overlap previous row by at least 25 mm.
Planks can be fastened with both nails or screws. It can be nailed directly to timber supports with round wire nails. When using metal screws, the size and length of the screw will be dependent on the thickness of the plank and the gauge of framing. Pre-drilling the plank is a must unless self-embedding, self-drilling head screws such as SHERA FIX-W32G8 are preferred.
No special tools are required. The product can be used with normal nails, fastened by normal or self-drilling screws and cut by electric power saw with diamond blade.
Fasteners must be located more than 12 mm from plank edges and 20 mm from plank ends. When installing in an overlapping plank cladding style, plank installation must be started at the bottom of the frame. The subsequent row of planks should overlap previous row by at least 25 mm.
SHERA Plank can be fixed to both timber frames (minimum size 1.5 x 3 inch) or steel frames (thickness between 0.55 and 1.6 mm). Framing must be selected to provide sufficient strength to support the SHERA Plank siding.
Soaker Jointer
Internal Corner Soaker
Galv Stud Clip
External Corner Soaker
SHERA Shiplap Plank can be fixed to both timber frames (minimum size 1.5 x 3 inch) or steel frames (thickness between 0.55 and 1.6 mm).
Framing must be selected to provide sufficient strength to support the SHERA Splendid Plank siding.
SHERA Planks can be fastened with nails or screws. It can be nailed directly to timber supports with round wire nails. When using metal screws, the size and length of the screw will be dependent on thickness of the Plank and the gauge of framing.
Pre-drilling the board is a must unless self-embedding, self-drilling head screws such as SHERA FIX-W32G8 are used.
No special tools are required. The product can be used with normal nails, fastened by normal or self-drilling screws and cut by electric power saw with diamond blade.
Fasteners must be located at more than 12 mm from plank edges and 20 mm from plank ends.
SHERA Plank installation must be started at the bottom of the frame.
Ship-lapping widths for each profile are different, see Installation manual for effective cover of each profile.
SHERA External Siding - English (pdf)
DownloadFibre Cement products are highly resistant to termite attack
Class 1 Fire Resistant product
Fibre Cement board will not absorb water
High durability against impact
Copyright © 2024 Fibre Cement Building Solutions - All Rights Reserved.
This site is intended as a digital catalogue to display the SHERA Fibre Cement products available to our Pacific Islands, Micronesia and Papua New Guinea markets. Please check with your local merchant for availability of specific SHERA products.
We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.